Investigation of the influence of thermal modernization of panel residential buildings in Poltava on the humidity condition of panels in the joint zone
| dc.contributor.author | Kidenko, V. | |
| dc.contributor.author | Omer, M. | |
| dc.contributor.author | Musaad, M. | |
| dc.contributor.author | Havrylenko, P. | |
| dc.date.accessioned | 2021-05-05T08:49:56Z | |
| dc.date.available | 2021-05-05T08:49:56Z | |
| dc.date.issued | 2021 | |
| dc.description | Investigation of the influence of thermal modernization of panel residential buildings in Poltava on the humidity condition of panels in the joint zone / V. Kidenko, M. Omer, M. Musaad, P. Havrylenko ; advisors : O. Yurin, N. Mahas // Black Sea Science 2021 : proc. of the Intern. Competition of Student Scientific Works / Odessa National Academy of Food Technologies ; eds. B. Yegorov, M. Mardar [et al.]. – Odessa: ONAFT, 2021. – P. 579–591 : fig. – Ref.: 7 tit. | ru_RU |
| dc.description.abstract | The paper studies the moisture condition of panels in the joint area to thermo-modernization. It was determined that there was no moisture condensation in the joints of 300 mm thick wall panels, while in 350 mm thick panels moisture accumulation occurred in winter, and the condensation zone was located in the thermal insulation of the joint near the windproof layer. After thermo-modernization of the panel walls, the moisture conditions in the joint area have improved, but in the 350 mm thick walls with an open drainage gap the second requirement of the norm is not met either. When the drainage gap is closed with additional insulation, the moisture conditions satisfy the norms. | ru_RU |
| dc.identifier.uri | https://card-file.ontu.edu.ua/handle/123456789/17596 | |
| dc.language.iso | en_US | ru_RU |
| dc.subject | joints of panel walls | ru_RU |
| dc.subject | humidity | ru_RU |
| dc.subject | thermal modernization of walls | ru_RU |
| dc.title | Investigation of the influence of thermal modernization of panel residential buildings in Poltava on the humidity condition of panels in the joint zone | ru_RU |
| dc.type | Article | ru_RU |
Файли
Контейнер файлів
1 - 1 з 1
Вантажиться...
- Назва:
- Black_Sea_Sci_2021_Kidenko.pdf
- Розмір:
- 6.21 MB
- Формат:
- Adobe Portable Document Format
- Опис:
Ліцензійна угода
1 - 1 з 1
Вантажиться...
- Назва:
- license.txt
- Розмір:
- 1.71 KB
- Формат:
- Item-specific license agreed upon to submission
- Опис: