Investigation of the influence of thermal modernization of panel residential buildings in Poltava on the humidity condition of panels in the joint zone
Вантажиться...
Дата
2021
Назва журналу
Номер ISSN
Назва тому
Видавець
Анотація
The paper studies the moisture condition of panels in the joint area to
thermo-modernization. It was determined that there was no moisture condensation in
the joints of 300 mm thick wall panels, while in 350 mm thick panels moisture
accumulation occurred in winter, and the condensation zone was located in the thermal
insulation of the joint near the windproof layer. After thermo-modernization of the
panel walls, the moisture conditions in the joint area have improved, but in the 350 mm
thick walls with an open drainage gap the second requirement of the norm is not met
either. When the drainage gap is closed with additional insulation, the moisture
conditions satisfy the norms.
Опис
Investigation of the influence of thermal modernization of panel residential buildings in Poltava on the humidity condition of panels in the joint zone / V. Kidenko, M. Omer, M. Musaad, P. Havrylenko ; advisors : O. Yurin, N. Mahas // Black Sea Science 2021 : proc. of the Intern. Competition of Student Scientific Works / Odessa National Academy of Food Technologies ; eds. B. Yegorov, M. Mardar [et al.]. – Odessa: ONAFT, 2021. – P. 579–591 : fig. – Ref.: 7 tit.
Ключові слова
joints of panel walls, humidity, thermal modernization of walls